레이블이 sewage treatment plant인 게시물을 표시합니다. 모든 게시물 표시
레이블이 sewage treatment plant인 게시물을 표시합니다. 모든 게시물 표시

2016년 3월 21일 월요일

Sewage Treatment Innovation with Microbial Technology


sewage treatment plant Sewage Treatment Sewage Treatment Innovation with Microbial Technology emma saunders 1
Biotal Marine has developed Biotal MDS 3000, a unique microbial product for the marine industry.
Developed through years of industry-leading research and development, Biotal MDS 3000 has been created to provide a holistic sewage treatment and ship maintenance package. The specifically chosen bacteria in the products are able to efficiently break down uric acid, reducing its ability to form uric scale.
Since 2008, all ships need to be equipped with an approved sewage treatment plant, under the Annex IV revisions from the International Convention for the Prevention of Pollution from Ships (MARPOL).
One of the biggest issues affecting sewage collection systems is the build-up of black water scale in sewage vacuum systems or sewage holding tanks. Safely neutralising the harmful bacteria found in the collection systems is an important issue, and often requires the use of harsh chemicals that are expensive and inefficient.
Black water is commonly caused from flush water and urine that over time forms scale in pipes and process equipment. The build-up of scale is aggravated by the action of the sewage vacuum and the effects of heat in the engine room both increase the evaporation rates of water within the shipping pipes and therefore speed up scale deposition.
Scale build-up within black water pipes eventually leads to blockages and foul odours, which can be an expensive, and time consuming issue to resolve.
The bacteria also prevents the build-up of organic and inorganic scale and matter in sanitation piping systems. The bacteria is able to degrade greases, oils, fats and other organic waste found in sewage pipes and drains, and this reduces the build-up of sludge and deposits in sewage plants and holding tanks.
The bacteria inside Biotal MDS 3000 are able to maintain pipes as they form a biofilm throughout the inside of the drain system, which is chemical and heat resistant, and is able to regenerate following any damage. The bacteria within the biofilm continue to produce enzymes for continuous organic matter and uric acid degradation.
Because the bacteria are specifically selected to break down uric acid and organic matter, Biotal Marine products deliver a targeted and efficient cleaning performance, in comparison with harsher chemicals that have a more general application process.
The use of natural microbes also makes Biotal marine products safer to apply than chemicals, and safer to store and handle for onboard employees. They also have a minimal impact on natural marine ecosystems.
Another advantage of using Biotal MDS 3000 is economic sustainability. After application, the microbes in the formula cultivate in the pipes and sewage collection systems and then continue working. This ensures the products continue working after application. In the long-term this can reduce shipping maintenance costs.
Biotal Marine research and development specialist Emma Saunders said: “Sewage treatment is an essential part of all ship maintenance. Products currently on the market that are used to maintain sewage collection systems are ineffective in preventing scale build-up, and often use harsh and unsafe chemistries to degrade organic and inorganic material.
“That is why we developed Biotal MDS 3000: to provide a far more cost-effective and eco-friendly sewage treatment product for the shipping and marine industry.
“By creating organic microbial cleaning solutions, we are able to offer a holistic cleaning alternative to harsher chemical products that are harmful to the environment, costly, and economically unsustainable.”
Sourced by ekomeri.com

Sewage Treatment Plant on a Ship Explained

Discarding sewage produced onboard on a ship is one of the few tasks on a ship which should be taken utmost care of if one wants to same him and his shipping company from heavy fine. The sewage generated on the ship cannot be stored on the ship for a very long time and it for this reason it has to be discharged into the sea.
Though sewage can be discharged into the sea, we cannot discharge it directly overboard as there are some regulations regarding discharging of sewage that needs to be followed. Sewage on sea is generally the waste produced from toilets, urinals and WC scuppers. The rules say that the sewage can be discharged into the sea water only after it is treated and the distance of the ship is 4 nautical miles from the nearest land.
But if the sewage is not treated this can be discharged 12 nautical miles away from the nearest land. Also the discharged sewage should not produce any visible floating solids nor should it cause any discoloration of surrounding water.
Generally, ships prefer treating sewage before discharging to save themselves from any type of embarrassment. There are different methods of treating sewage available in the market, but the most common of them is the biological type for it occupies less space for holding tank, unlike those of the other methods. Moreover, the discharge generated from this plant is eco friendly. It is to not that each sewage treatment system installed onboard has to be certified by classification society and should perform as per their requirement and regulations. 
Working of a Biological Sewage Plant
The basic principle of the working of a biological treatment plant is decomposition of the raw sewage. This process is done by aerating the sewage chamber with fresh air. The aerobic bacteria survive on this fresh air and decompose the raw sewage which can be disposed off in the sea. Air is a very important criterion in the functioning of the biological sewage plant because if air is not present, it will lead to growth of anaerobic bacteria, which produces toxic gases that are hazardous to health.Also, after decomposition of the sewage with anaerobic bacteria, a dark black liquid causes discoloration of water which is not accepted for discharging. Thus in a biological sewage treatment plant the main aim is to maintain the flow of fresh air.
Chamber of Biological Sewage Plant
Division of Processes
The biological sewage plant is divides into three chambers:- 
Aeration chamber
 This chamber is fed with raw sewage which has been grinded to form small particles. The advantage of breaking sewage in small particles is that it increases the area and high number of bacteria can attack simultaneously to decompose the sewage. The sewage is decomposed into carbon dioxide, water and inorganic sewage. The air is forced through diffuser into the air chamber. The pressure of air flow also plays an important role in decomposition of the sewage. If pressure is kept high then the mixture of air and sewage will not take place properly and it will escape without doing any work required for decomposition. It is for this reason; controlled pressure is important inside the sewage treatment plant as this will help in proper mixing and decomposition by the agitation caused by air bubbles. Generally the pressure is kept around 0.3-0.4 bars. 
Settling tank
The mixture of liquid and sludge is passed to settling tank from the aeration chamber. In the settling tank the sludge settles at the bottom and clear liquid on the top. The sludge present at the bottom is not allowed to be kept inside the settling tank as this will lead to growth of anaerobic bacteria and foul gases will be produced.The sludge formed is recycled with the incoming sludge where it will mixes with the later and assist in the breakdown of sewage. 
Chlorination and Collection
In this chamber the clear liquid produced from the settling tank is over flown and the liquid is disinfected with the help of chlorine. This is done because of the presence of the e-coli bacteria present in the liquid. To reduce these bacteria to acceptable level chlorination is done. Moreover, to reduce the e-coli, the treated liquid is kept for a period of at least 60 minutes. In some plants disinfection is also done with the help of ultra violet radiation. The collected liquid is discharged to overboard or settling tank depending on the geological position of the ship. If the ship is in restricted or near coastline then the sewage will be discharged into the holding tank; otherwise, the sewage is discharged directly into the sea when high level is reached and is disposed automatically until low level switch activates.

Types of Sewage Treatment

Legislation preventing the discharge of untreated waste overboard has been in place for some time with a requirement that it should be retrofitted where not already in use. American legislation defines three types of sewage treatment units.

Type Ⅰ  A device capable of discharging effluent having no floating solids and a coliform count of less than 1000 per 100ml of effluent.
Type II  A device capable of discharging effluent with suspended solids not in excess of 150mg/litre and a coliform count of less than 200 per 100ml.
Type III  A device to prevent the discharge overboard of treated or untreated waste.
Ventilation systems are to be kept independent of other vents A log is to be kept of any discharge overboard from a holding tank.


Aerobic (Biological) Treatment plant (Flow through system)

biological sewage treatment system
sewage treatment system of HOSEUNG ent.Co.,LTD
SEWAGE TREATMENT SYSTEM of HOSEUNG Ent.Co.,Ltd















Principle
Biological system requires a steady and relatively constant flow of solid sewage so the bacteria can exist in sufficient quantity to maintain effluent discharge at the correct quality. Sludge build up is a possible problem although extended residence in the aeration chamber greatly reduces the amount. For example, sewage with 80% solid waste is reduced to 20% of its original weight after 12 hours in the aeration tank.
The process of aerobicity strips oxygen from the water and creates more water, carbon dioxide and bacteria.
Operation
The Trident sewage treatment unit shown above consists of three chambers.
Sewage enters the aeration chamber via a coarse mesh filter where large solids are broken down. The aeration chamber is where the main biological action takes place. Here air blowers mounted on the outside of the unit oxygenate and stir the effluent and bacteria mix via a series of pipes and nozzles. The sewage remains in this aeration tank for some time.
Incoming sewage displaces some effluent of the settling tank (or hopper) where under inactive conditions biological floc, activated sludge and bacteria, settle out and is returned to the aeration chamber via air lift pumps also driven by the blowers. A second transfer pipe scum’s the surface of the settling tank and returns it back to the aeration chamber. This returned sludge contains the bacteria to digest the incoming sewage. Thus the importance of this floc return can be seen
Note:
This is a common question in orals
Effluent passing over from this chamber should be clean and ready for disinfecting in the chlorinating chamber. The level in this chamber is controlled by a pump and float switch arrangement. Typical chlorine levels at discharge is 5ppm.
Valves are fitted to the aeration and primary chambers to allow them to be pumped out and back flushed as necessary.
The bacteria are susceptible to water conditions including temperature and the presence of toilet cleaning agents. In this way the system is fitted with by-pass valves so passing contaminated water overboard. Should the bacteria be killed it takes some time before a new colony forms. There are special ‘feeds’ which promote the reestablishment of these colonies.


Physical-Chemical Sewage system

This is based on the separation of the liquid element from the sewage flow. This is disinfected in a 5% chlorine for 30 minutes to kill off coliform bacteria and then discharged overboard in full MARPOL compliance.
One problem with this system is the required space, only a finite amount of space can be set aside for the storage of the solid part of the waste which can only be discharged in port or outside territorial waters when allowed. If these facilities are unavailable the system becomes inoperative.
There is also the need to carry quantities of Calcium Hypochlorite for conversion to Sodium HypoChlorite for the disinfection of sewage flow. Calcium Hypochlorite requires very careful handling.

Electrocatalytic Oxidation

Electrocatalytic Oxidation(sewage treatment system)
Sewage is collected, macerated and passed through a electrolytic cell.
Electrolysis produces Sodium Hypochlorite which is used to oxidise organic material before discharge. Alternately dosing by chlorine may be used. The effluent passes on through to a settling tank were the oxidation process is completed.

These type of plants can be 50% smaller than biological types, this and the fact that pass through times are extremely short-typically 30 minutes compared to the several hours of the biological unit- are the main advantages of this system. The discharge contains no solids and is totally free of coliform bacteria.

A disadvantage of this system is due to the short exposure time in the oxidiser relatively high levels of chlorine are required to ensure destruction of the coliform bacteria. It is possible that this chlorine level can be present to some degree in the discharge.
Dechlorination plant may be fitted


Vacuum sewage systems

vacuumm sewage system

Operation
Liquid flows from the aeration tank of an aerobic sewage tank to a coarse impeller centrifugal pump. This delivers the liquid under pressure via an eductor and back to the tank. The eductor reduces the pressure in the sewage system pipework to a set point after which the pump is stopped. When the pressure in the pipework rises above a set value it is restarted.
The pipework consists of a network of mainly pvc pipes connected into separate zones- typically by deck- and brought down to a common manifold via isolating valves. These valves allow work on sections of the system whilst still maintaining others in use.
The toilets are connect to the system via a vacuum operated foot valve. Vacuum timers are also fitted which allow measured quantities of flushing water to be applied.
Where toilets are connected in the same zone but exist at different heights non-returning valves may be fitted. In addition filter boxes may be fitted along with additional isolating valves to improve operation.

Advantages and disadvantages
Very little flushing water is required and the volume of sewage dealt with can be much reduced with the downsizing of relevant equipment and cost saving.This has made them very popular for passenger vessels.Lloyds regulations state that the capacity of a sewage system for flushing water with conventional plant is 115 litres/ person/ day and 15 litres for vacuum systems.
The main disadvantage is blockage due to drying and crystalisation of urea. Over a period of time this can be so severe as to completely close the pipes. Chemicals are on the market which can be added in very small doses which help remove and prevent this deposit but there success is not guarenteed.
In the event of vacuum failure a method must be in place to prevent dangerous gasses passing back into the accommodation.